type: exampleresource: Deviceexample: device-example-AND20601BPMonitor
Device Example: device-example-AND20601BPMonitor
Example XML
<?xml version="1.0" encoding="UTF-8"?>
<Device xmlns="http://hl7.org/fhir"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://hl7.org/fhir http://hl7.org/fhir/device.xsd">
<id value="and20601bpmonitor"/>
<identifier>
<type>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"/>
<code value="SYSID"/>
<display value="System Identifier"/>
</coding>
</type>
<system value="urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"/>
<value value="00-09-1F-FF-FE-80-07-3A"/>
</identifier>
<identifier>
<type>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"/>
<code value="BTMAC"/>
<display value="Bluetooth Address"/>
</coding>
</type>
<system value="http://hl7.org/fhir/sid/eui-48"/>
<value value="00-09-1F-80-07-3A"/>
</identifier>
<udiCarrier>
<deviceIdentifier value="39183189818" />
<issuer value="http://hl7.org/fhir/NamingSystem/gs1-di" />
<jurisdiction value="http://hl7.org/fhir/NamingSystem/fda-udi" />
<carrierHRF value="(01)39183189818(21)5091100966" />
<entryType value="unknown" />
</udiCarrier>
<manufacturer value="A&D Medical" />
<serialNumber value="5091100966" />
<name>
<value value="AND BP UA-767PBT-C" />
<type>
<coding>
<system value="http://hl7.org/fhir/device-nametype"/>
<code value="user-friendly-name"/>
</coding>
</type>
</name>
<modelNumber value="UA-767PBT-C"/>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="65573"/>
<display value="MDC_MOC_VMS_MDS_SIMP"/>
</coding>
<text value="MDC_MOC_VMS_MDS_SIMP: Personal Health Device"/>
</type>
<deviceVersion>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101" />
<code value="532352" />
</coding>
<text value="MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version" />
</type>
<value value="1.0" />
</deviceVersion>
<conformsTo>
<specification>
<coding>
<system value="urn:iso:std:iso:11073:10101" />
<code value="528391" />
</coding>
<text value="MDC_DEV_SPEC_PROFILE_BP: Blood Pressure meter" />
</specification>
<version value="1" />
</conformsTo>
<property>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101" />
<code value="532353" />
</coding>
<text value="MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list" />
</type>
<valueCodeableConcept>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/ContinuaPAN" />
<code value="7" />
</coding>
</valueCodeableConcept>
</property>
<property>
<type>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7" />
<code value="532354.0" />
<display value="regulation-status" />
</coding>
</type>
<valueCodeableConcept>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/v2-0136" />
<code value="N" />
</coding>
<text value="Device is Regulated" />
</valueCodeableConcept>
</property>
<property>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101" />
<code value="68220" />
</coding>
<text value="MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol" />
</type>
<valueCodeableConcept>
<coding>
<system value="urn:iso:std:iso:11073:10101" />
<code value="532224" />
</coding>
<text value="MDC_TIME_SYNC_NONE: No time synchronization" />
</valueCodeableConcept>
</property>
<property>
<type>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7" />
<code value="68219.0" />
</coding>
<text value="mds-time-capab-real-time-clock" />
</type>
<valueCodeableConcept>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/v2-0136" />
<code value="Y" />
</coding>
<text value="real time clock supported" />
</valueCodeableConcept>
</property>
<property>
<type>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7" />
<code value="68219.1" />
</coding>
<text value="mds-time-capab-set-clock" />
</type>
<valueCodeableConcept>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/v2-0136" />
<code value="Y" />
</coding>
<text value="setting the time supported" />
</valueCodeableConcept>
</property>
<property>
<type>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7" />
<code value="68219.11" />
</coding>
<text value="mds-time-mgr-set-time" />
</type>
<valueCodeableConcept>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/v2-0136" />
<code value="Y" />
</coding>
<text value="manager requested to set the time" />
</valueCodeableConcept>
</property>