View raw Markdown
type: codesystemcodesystem: imagingselection-status

Imaging Selection Status

Concepts

CodeDisplayDefinition
availableAvailableThe selected resources are available..
entered-in-errorEntered in ErrorThe imaging selection has been withdrawn following a release. This electronic record should never have existed, though it is possible that real-world decisions were based on it. (If real-world activity has occurred, the status should be "inactive" rather than "entered-in-error".).
inactiveInactiveThe imaging selection is no longer valid.
unknownUnknownThe system does not know which of the status values currently applies for this request. Note: This concept is not to be used for "other" - one of the listed statuses is presumed to apply, it's just not known which one.

CodeSystem XML

<?xml version="1.0" encoding="UTF-8"?>

<CodeSystem xmlns="http://hl7.org/fhir">
  <id value="imagingselection-status"/>
  <meta>
    <lastUpdated value="2022-06-29T10:01:24.148+11:00"/>
  </meta>
  <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
    <valueCode value="ii"/>
  </extension>
  <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status">
    <valueCode value="normative"/>
  </extension>
  <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm">
    <valueInteger value="6"/>
  </extension>
  <url value="http://hl7.org/fhir/imagingselection-status"/>
  <identifier>
    <system value="urn:ietf:rfc:3986"/>
    <value value="urn:oid:2.16.840.1.113883.4.642.4.1985"/>
  </identifier>
  <version value="6.0.0"/>
  <name value="ImagingSelectionStatus"/>
  <title value="Imaging Selection Status"/>
  <status value="active"/>
  <experimental value="false"/>
  <date value="2024-06-13"/>
  <publisher value="HL7 (FHIR Project)"/>
  <contact>
    <telecom>
      <system value="url"/>
      <value value="http://hl7.org/fhir"/>
    </telecom>
    <telecom>
      <system value="email"/>
      <value value="fhir@lists.hl7.org"/>
    </telecom>
  </contact>
  <description value="The status of the ImagingSelection."/>
  <caseSensitive value="true"/>
  <valueSet value="http://hl7.org/fhir/ValueSet/imagingselection-status"/>
  <content value="complete"/>
  <concept>
    <code value="available"/>
    <display value="Available"/>
    <definition value="The selected resources are available.."/>
  </concept>
  <concept>
    <code value="entered-in-error"/>
    <display value="Entered in Error"/>
    <definition value="The imaging selection has been withdrawn following a release.  This electronic record should never have existed, though it is possible that real-world decisions were based on it. (If real-world activity has occurred, the status should be "inactive" rather than "entered-in-error".)."/>
  </concept>
  <concept>
    <code value="inactive"/>
    <display value="Inactive"/>
    <definition value="The imaging selection is no longer valid."/>
  </concept>
  <concept>
    <code value="unknown"/>
    <display value="Unknown"/>
    <definition value="The system does not know which of the status values currently applies for this request. Note: This concept is not to be used for "other" - one of the listed statuses is presumed to apply, it's just not known which one."/>
  </concept>
</CodeSystem>