View raw Markdown
type: codesystemcodesystem: devicealert-presence

Device Alert Presence

Concepts

CodeDisplayDefinition
onOnThe signal is annunciated due to the presence of the alert condition
latchedLatchedThe signal is annunciated after the alert condition is no longer present, until it is stopped by deliberate operator action
offOffThe signal is not being annunciated and the alert condition is no longer present
ackAcknowledgedThe signal is no longer annunciated having been stopped by deliberate operator action although the alert condition is still present

CodeSystem XML

<?xml version="1.0" encoding="UTF-8"?>

<CodeSystem xmlns="http://hl7.org/fhir">
  <id value="devicealert-presence"/>
  <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
    <valueCode value="dev"/>
  </extension>
  <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status">
    <valueCode value="normative"/>
  </extension>
  <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm">
    <valueInteger value="2"/>
  </extension>
  <url value="http://hl7.org/fhir/devicealert-presence"/>
  <version value="6.0.0"/>
  <name value="DeviceAlertPresence"/>
  <title value="Device Alert Presence"/>
  <status value="active"/>
  <experimental value="false"/>
  <date value="2023-12-10T10:01:24+11:00"/>
  <publisher value="HL7 International / Health Care Devices"/>
  <contact>
    <telecom>
      <system value="url"/>
      <value value="http://www.hl7.org/Special/committees/healthcaredevices"/>
    </telecom>
    <telecom>
      <system value="email"/>
      <value value="fhir@lists.hl7.org"/>
    </telecom>
  </contact>
  <description value="Describes the Presence of a DeviceAlert."/>
  <caseSensitive value="true"/>
  <valueSet value="http://hl7.org/fhir/ValueSet/devicealert-presence"/>
  <content value="complete"/>
  <concept>
    <code value="on"/>
    <display value="On"/>
    <definition value="The signal is annunciated due to the presence of the alert condition"/>
  </concept>
  <concept>
    <code value="latched"/>
    <display value="Latched"/>
    <definition value="The signal is annunciated after the alert condition is no longer present, until it is stopped by deliberate operator action"/>
  </concept>
  <concept>
    <code value="off"/>
    <display value="Off"/>
    <definition value="The signal is not being annunciated and the alert condition is no longer present"/>
  </concept>
  <concept>
    <code value="ack"/>
    <display value="Acknowledged"/>
    <definition value="The signal is no longer annunciated having been stopped by deliberate operator action although the alert condition is still present"/>
  </concept>
</CodeSystem>