View raw Markdown
type: codesystemcodesystem: audit-event-severity

Audit Event Severity

Concepts

CodeDisplayDefinition
emergencyEmergencySystem is unusable. e.g., This level SHOULD only be reported by infrastructure and SHOULD NOT be used by applications.
alertAlertNotification SHOULD be sent to trigger action be taken. e.g., Loss of the primary network connection needing attention.
criticalCriticalCritical conditions. e.g., A failure in the system's primary application that will reset automatically.
errorErrorError conditions. e.g., An application has exceeded its file storage limit and attempts to write are failing.
warningWarningWarning conditions. May indicate that an error will occur if action is not taken. e.g., A non-root file system has only 2GB remaining.
noticeNoticeNotice messages. Normal but significant condition. Events that are unusual, but not error conditions.
informationalInformationalNormal operational messages that require no action. e.g., An application has started, paused, or ended successfully.
debugDebugDebug-level messages. Information useful to developers for debugging the application.

CodeSystem XML

<?xml version="1.0" encoding="UTF-8"?>

<CodeSystem xmlns="http://hl7.org/fhir">
  <id value="audit-event-severity"/>
  <meta>
    <lastUpdated value="2022-06-06T10:01:24.148+11:00"/>
  </meta>
  <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
    <valueCode value="sec"/>
  </extension>
  <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status">
    <valueCode value="normative"/>
  </extension>
  <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm">
    <valueInteger value="6"/>
  </extension>
  <url value="http://hl7.org/fhir/audit-event-severity"/>
  <identifier>
    <system value="urn:ietf:rfc:3986"/>
    <value value="urn:oid:2.16.840.1.113883.4.642.4.1894"/>
  </identifier>
  <version value="6.0.0"/>
  <name value="AuditEventSeverity"/>
  <title value="Audit Event Severity"/>
  <status value="active"/>
  <experimental value="false"/>
  <date value="2025-11-01"/>
  <publisher value="HL7 International / Security"/>
  <contact>
    <telecom>
      <system value="url"/>
      <value value="http://www.hl7.org/Special/committees/secure"/>
    </telecom>
    <telecom>
      <system value="email"/>
      <value value="fhir@lists.hl7.org"/>
    </telecom>
  </contact>
  <description value="The severity of the audit entry. These codes are derived from the SysLog header, PRI. http://tools.ietf.org/html/rfc5424#appendix-A.3"/>
  <caseSensitive value="true"/>
  <valueSet value="http://hl7.org/fhir/ValueSet/audit-event-severity"/>
  <content value="complete"/>
  <concept>
    <code value="emergency"/>
    <display value="Emergency"/>
    <definition value="System is unusable. e.g., This level SHOULD only be reported by infrastructure and SHOULD NOT be used by applications."/>
  </concept>
  <concept>
    <code value="alert"/>
    <display value="Alert"/>
    <definition value="Notification SHOULD be sent to trigger action be taken. e.g., Loss of the primary network connection needing attention."/>
  </concept>
  <concept>
    <code value="critical"/>
    <display value="Critical"/>
    <definition value="Critical conditions. e.g., A failure in the system's primary application that will reset automatically."/>
  </concept>
  <concept>
    <code value="error"/>
    <display value="Error"/>
    <definition value="Error conditions. e.g., An application has exceeded its file storage limit and attempts to write are failing. "/>
  </concept>
  <concept>
    <code value="warning"/>
    <display value="Warning"/>
    <definition value="Warning conditions. May indicate that an error will occur if action is not taken. e.g., A non-root file system has only 2GB remaining."/>
  </concept>
  <concept>
    <code value="notice"/>
    <display value="Notice"/>
    <definition value="Notice messages. Normal but significant condition. Events that are unusual, but not error conditions."/>
  </concept>
  <concept>
    <code value="informational"/>
    <display value="Informational"/>
    <definition value="Normal operational messages that require no action. e.g., An application has started, paused, or ended successfully."/>
  </concept>
  <concept>
    <code value="debug"/>
    <display value="Debug"/>
    <definition value="Debug-level messages. Information useful to developers for debugging the application."/>
  </concept>
</CodeSystem>